Matrixx Infusion SupportSystem Start Up

Matrixx Infusion Support

System Start Up

1

With the bypass handle in the bypass position, initiate an immediate regeneration

This will advance the valve to the backwash position.

2

Once the valve has stopped moving and is in the backwash position, slowly open the bypass handle about 1/8th turn

Water should slowly enter the tank.

NOTE: If there is a loud knocking sound, simply turn the bypass handle back slightly as the system is filling too quickly.

3

During the backwash cycle, slowly open the bypass valve until there is water coming out of the drain hose

Then open the bypass valve fully. During this process, peroxide should be injecting into the system.

4

Allow the system to backwash and push all the air out through the drain

5

Allow the unit to rinse for the entire cycle

The water in the drain should be running clear by the end of the Rapid Rinse Cycle.

6

The valve will then advance to Service

7

Once the system has returned to the Service position, the system is installed and ready for use